12 Panel Vacuum Urine Cup – Collection Kit
Key Features:Â
Rapid Results: Get accurate readings within 5 minutes.
All-Inclusive Kit: Includes a 120ml test cup, a secure lid with a needle, a vacuum collection tube, gloves, an alcohol swab, and a zip-lock specimen bag.
User-Friendly Design: Easy-to-follow steps for quick administration.
Temperature Check: Built-in strip ensures specimen validity.
Secure Handling: Features a tamper-evident security seal.
CLIA & FDA approved
Long shelf Life:Â 24 months from the date of manufacture
Drug Name/Abbreviation | Cut-Off Level | Detection time Urine |
Amphetamines/AMP | 1000 ng/mL | 1-2 Days |
Barbiturates/BAR | 300 ng/mL | 1-4 Days |
Benzodiazepines/BZO | 300 ng/mL | 1-2 Days |
Buprenorphine/BUP | 10 ng/mL | 2-6 Days |
Cocaine/COC | 300 ng/mL | 2-4 Days |
Ecstasy/MDMA | 500 ng/mL | 2-4 Days |
Marijuana/THC | 50 ng/mL | 5+ Days |
Methadone/MTD | 300 ng/mL | 1-3 Days |
Methamphetamine/mAMP (or MET) | 1000 ng/mL | 2-4 Days |
Morphine/OPI | 300 ng/mL | 2-3 Days |
Oxycodone/OXY | 100 ng/mL | 1-3 Days |
Phencyclidine/PCP | 25 ng/mL | 7-14 Days |
12 Panel Drug test instruction
The 12 panel PCP drug test cup should be stored in temperatures between 36 and 78 degrees fahrenheit. Remember to not remove the seals of the drug test cups until they are ready to use. Interfering with the designated process could give false positive results or even false negatives.
Be sure to follow the instructions when using the 12 panel drug testing cups.
- Open The drug testing device should be held at temperatures between 36 and 78 degrees Fahrenheit. If this is followed the cup can be removed from the packaging slowly.
- Collect Urine should be administered into the open cup only once you are ready to use the device, otherwise, it should remain closed.
- Check Once the urine is in, the temperature strips on the cup should show a temperature of between 90 and 100 degrees Fahrenheit.
- Wait Once the urine has been administered and the cup closed, wait for 5 minutes at least, if you check the test sooner than that the results will be inconclusive.
- Peal Once the 5 minutes have passed you can read the results of the test by looking at the test strips membrane which is printed out on the cup itself.
- Read Following the instructions on how to read the test, take a look at the membranes of the strips, keep a close eye on the C and T markings.
12 Panel Vacuum Kit Drug Test
The 12 Panel Vacuum Kit Drug Test is the ultimate solution for accurate, efficient, and hygienic urine drug testing. Designed to simplify the sample collection and testing process, this kit comes equipped with a vacuum urine cup, 12 panel lid vacuum cup, and vacuum urine collection tubes, making it ideal for workplaces, clinical settings, law enforcement, and more.
Key Features:
- Vacuum Urine Cup: The kit features a vacuum urine cup that ensures a clean and simple urine collection process. The cup is designed to minimize spillage and contamination, providing a secure sample environment.
- Urine Collection Cup with Integrated Transfer Device: This urine collection cup with integrated transfer device allows for direct, hassle-free transfer of the urine sample into vacuum-sealed tubes. With no need for additional transfer tools, this feature enhances the speed and convenience of the testing process.
- 12 Panel Lid Vacuum Cup: The included 12 panel lid vacuum cup is specifically designed for comprehensive drug testing. The lid features an integrated transfer device that enables the direct transfer of urine into vacuum-sealed tubes, ensuring a precise and mess-free process.
- Vacuum Urine Collection Tubes: The vacuum urine collection tubes are designed to create an airtight seal, preserving the integrity of the sample for reliable laboratory analysis. The vacuum seal ensures the sample remains uncontaminated during transport and storage.
- Integrated Transfer Device: The integrated transfer device built into the cup and lid allows for direct transfer into tubes without exposure to external elements. This feature is essential for maintaining sample accuracy and minimizing the risk of contamination.
How to Use:
- Collect the Sample: Instruct the donor to provide a urine sample using the vacuum urine cup. Once the sample is collected, secure the tamper-evident lid.
- Transfer the Sample: Use the integrated transfer device on the lid to transfer the sample into the vacuum urine collection tubes. Simply press the tube onto the transfer device, and the vacuum mechanism will automatically draw the urine, sealing it securely.
- Label and Send: Label the tubes for proper identification and send them to the lab for analysis. The vacuum-sealed tubes ensure the sample remains stable and uncontaminated until testing.
Interpret the Results of drug test vacuum cup:
- Negative Result:
- A negative result means that the drug being tested is not present or below the detectable limit. You will see two lines on the panel—one line in the Control (C) area and one line in the Test (T) area.
- The lines do not have to be of equal darkness; even a faint test line next to a clear control line is considered a negative result.
- Positive Result:
- A positive result means that the drug is present at or above the detectable limit. You will see one line in the Control (C) area, but no line in the Test (T) area.
- The absence of the test line indicates a positive result for that specific drug.
- Invalid Result:
- An invalid result occurs if no line appears in the Control (C) area, regardless of whether a line appears in the Test (T) area.
- This indicates that the test did not run correctly and should be discarded. A new test should be conducted using a fresh cup.