120ml 10 Panel Drug Test with Kratom, Fentanyl, K2 & EtG
$4.49 Original price was: $4.49.$1.99Current price is: $1.99.
This 120ml 10 panel drug test with kratom and fentanyl combines KRA/500, FEN/20, K2/50 and EtG/300 with six additional screening panels. The Serenity cup provides preliminary screening in a 120ml format identified by SKU SM-CDOA-9105-FUO.
- 120ml Serenity drug test cup
- Kratom panel at a 500 ng/mL cutoff
- Dedicated fentanyl panel at a 20 ng/mL cutoff
- K2/Spice at 50 ng/mL and EtG alcohol-metabolite screening at 300 ng/mL
- Results read according to the included product instructions
- Product code: SM-CDOA-9105-FUO
- Bulk quantity pricing available
FREE SHIPPING on qualifying orders of 100 cups or more.
| 10 Panel Drug Test Cup |
| Â COC/300, OPI/300, MET/1000, BZO/300, FEN/20, ETG/300, OXY/100, K2/50, BUP/10, KRA/500 |
Printable result form for this cup
Record panel results, specimen checks and signatures. Free fillable PDF.
Download Result Form (PDF) See all result forms →120ml 10 Panel Drug Test with Kratom and Fentanyl
The Serenity 120ml 10 panel drug test with kratom and fentanyl brings KRA, fentanyl, K2 and EtG screening together in one cup. These four panels are included within the total of ten, alongside cocaine, opiates, methamphetamine, benzodiazepines, oxycodone and buprenorphine. Each assay provides its own preliminary screening result.
This configuration is an option for buyers comparing a 10 panel drug test without THC that includes both kratom and fentanyl. The 90ml kratom model has a different drug list, so choosing between them involves more than cup capacity. Match every required panel and cutoff before selecting a product.
The dedicated fentanyl panel has a 20 ng/mL cutoff and is separate from the OPI/300, OXY/100 and BUP/10 panels. This distinction helps you compare the specific opioid-related assays included in each cup. A ten-panel label alone does not identify which substances a product screens for.
The 120ml specification describes cup capacity; follow the supplied instructions for the required sample volume. Use SKU SM-CDOA-9105-FUO when ordering this combination or comparing it with other 10 panel drug test cups. Review the labeled intended use and instructions before testing.
10 Panel Drug Test Cutoff Levels
The following table lists all ten panels and their screening cutoff levels for this 120ml configuration. The values are expressed in nanograms per milliliter (ng/mL).
| Drug or Drug Class | Abbreviation | Cutoff Level |
|---|---|---|
| Buprenorphine | BUP | 10 ng/mL |
| Benzodiazepines | BZO | 300 ng/mL |
| Cocaine | COC | 300 ng/mL |
| Ethyl Glucuronide (Alcohol Metabolite) | ETG | 300 ng/mL |
| Fentanyl | FEN | 20 ng/mL |
| Synthetic Cannabinoids (K2/Spice) | K2 | 50 ng/mL |
| Kratom | KRA | 500 ng/mL |
| Methamphetamine | MET | 1,000 ng/mL |
| Opiates | OPI | 300 ng/mL |
| Oxycodone | OXY | 100 ng/mL |
A screening cutoff is an assay threshold. It does not describe the amount consumed, establish impairment or provide a guaranteed detection period.
Understanding the Kratom, Fentanyl, K2 and EtG Panels
Kratom: the KRA panel is listed at 500 ng/mL. Its exact target and response to related compounds must be checked in the cup’s insert. Our 7-OH and kratom testing guide explains why specifications from a separate kratom strip cannot automatically be applied to this cup.
Fentanyl:Â this product includes a dedicated FEN panel at 20 ng/mL. Read that assay separately from the opiate, oxycodone and buprenorphine assays. A result on one panel does not determine the results on the others.
K2/Spice:Â the K2 panel has a 50 ng/mL cutoff. Coverage depends on the compounds identified in the exact assay documentation; it should not be interpreted as detection of every synthetic cannabinoid.
EtG: ethyl glucuronide is an alcohol metabolite, screened here at 300 ng/mL. This panel does not measure blood alcohol concentration or establish current impairment. Detection varies with factors including exposure and collection timing. See ARUP’s alcohol biomarker guidance for background on EtG.
Compare 120ml and 90ml Drug Test Cup Options
The 90ml 10 panel cup with kratom, K2 and EtG includes THC at 50 ng/mL instead of fentanyl. The remaining nine listed panels and cutoff levels match this 120ml configuration. Choose according to the required drug list as well as cup capacity.
For another combination containing fentanyl and EtG, compare the 120ml EtG and fentanyl drug test cup. That product includes AMP, PCP and THC, uses an OPI cutoff of 2,000 ng/mL, and has no dedicated KRA, K2 or OXY panels.
How to Use a 10 Panel Drug Test Cup
Follow the instructions supplied with the exact device for specimen requirements, preparation, activation and reading time. Our Serenity cup drug testing instructions provide supporting guidance.
- Check the device. Confirm the product configuration, expiration date and intact packaging. Read the supplied instructions before opening the cup.
- Collect the specimen. Follow the specified collection procedure and fill requirement. Cup capacity does not indicate how much sample is required.
- Run the test. Secure the lid and complete any activation steps described in the insert. Follow the stated placement and timing requirements.
- Read and record each assay. Check the control and test lines within the specified reading window. Record results by drug abbreviation and do not interpret changes after the permitted time.

How to Read the Drug Test Cup Results
Interpret each drug assay separately and within the reading time specified in the supplied instructions.
| Control Line C | Test Line T | Screening Result |
|---|---|---|
| Visible | Visible, including a faint colored line | Negative screen for that assay |
| Visible | Absent | Preliminary non-negative screen for that assay |
| Absent | Visible or absent | Invalid assay |
A faint colored test line counts when the control line is present and the result is read within the valid window. Line darkness does not measure drug concentration. An invalid assay requires repeat testing according to the insert; a preliminary non-negative result requires appropriate laboratory confirmation.
See our guide to reading a drug test cup for further explanation of negative, non-negative and invalid results.
Ordering the 120ml Kratom and Fentanyl Test Cup
Check the quantity pricing displayed for SKU SM-CDOA-9105-FUO. For a larger order, use our wholesale drug testing supplies page and provide the SKU, required quantity and delivery destination. Using the same SKU on repeat orders helps maintain the intended panel configuration.
Intended use: use the device according to its specific labeling and supplied instructions. Review our Forensic Use Only and Employment & Insurance guidance for an explanation of these designations. The designation applicable to the individual product controls.
Frequently Asked Questions
Does this 10 panel drug test include fentanyl?
Yes. This 120ml cup includes a dedicated fentanyl panel with a 20 ng/mL cutoff. Fentanyl is one of the ten included panels, alongside KRA, K2, EtG, COC, OPI, MET, BZO, OXY and BUP.
Does this cup include THC?
No. This configuration has no dedicated THC panel. The separate 90ml kratom, K2 and EtG cup includes THC instead of fentanyl, so the two products differ in both capacity and panel configuration.
Can the KRA panel confirm 7-OH use?
The KRA/500 designation alone does not establish this cup’s response to 7-OH. Check the exact cup insert for its target and cross-reactivity information. Specifications from a separate kratom strip do not automatically apply, and a screening result is not definitive confirmation.
Does the EtG panel measure current intoxication?
No. The EtG panel screens for ethyl glucuronide, an alcohol metabolite, at a 300 ng/mL cutoff. It does not measure blood alcohol concentration or establish current impairment. A fixed detection period cannot be guaranteed.
How much sample does a 120ml cup require?
The 120ml specification describes cup capacity, not the required sample volume. Follow the fill level and collection requirements in the instructions supplied with the exact device.
What does a missing control line mean?
The affected assay is invalid, whether the test line is visible or absent. Do not report it as negative or non-negative. Review the procedure and repeat with a new device as directed by the supplied instructions.
| Weight | 0.14 lbs |
|---|---|
| Dimensions | 5 × 3 × 3 in |
| Drug tested | BUP, BZO, COC, EtG, FEN, K2/Spice, KRA, MET, OPI/MOR, OXY |
You must be logged in to post a review.


All orders will only be shipped same-day if they are placed before 3.00pm EST time. Also next day shipments will not be delivered on weekends and that the time taken on air shipments should be counted with business days.



Reviews
There are no reviews yet.