120ml 10 Panel Drug Test Cup with K2, MDMA & OPI2000

Original price was: $2.99.Current price is: $2.59.

This 120ml 10 panel drug test cup with K2 combines dedicated K2/Spice and MDMA panels with eight additional drug-screening panels. The Serenity cup includes OPI/2000 and separate THC, buprenorphine and oxycodone assays for preliminary screening.

  • 120ml Serenity drug test cup
  • K2/Spice panel at a 50 ng/mL cutoff
  • Separate MDMA/500 and THC/50 panels
  • Opiate screening at a 2,000 ng/mL cutoff
  • Results read according to the included product instructions
  • Product code: SM-CDOA-1104K-FUO
  • Bulk quantity pricing available

FREE SHIPPING on qualifying orders of 100 cups or more.

10 Panel Drug Test Cup
AMP/1000, BUP/10, BZO/300, COC/300, K2/50, MDMA/500, MET/1000, OPI/2000, OXY/100, THC/50
Buy 25 pieces and save 13%
$2.99
$2.59
Total:
$2.99
Buy 50 pieces and save 15%
$2.99
$2.55
Total:
Buy 100 pieces and save 17%
$2.99
$2.49
Total:
Buy 200 pieces and save 18%
$2.99
$2.45
Total:
Buy 400 pieces and save 20%
$2.99
$2.39
Total:
Buy 600 pieces and save 23%
$2.99
$2.29
Total:
Buy 800 pieces and save 27%
$2.99
$2.19
Total:
Buy 1,000 pieces and save 30%
$2.99
$2.09
Total:
Buy 2,000 pieces and save 31%
$2.99
$2.05
Total:
Buy 4,000 pieces and save 33%
$2.99
$1.99
Total:
Buy 6,000 pieces and save 37%
$2.99
$1.89
Total:
Buy 8,000 pieces and save 40%
$2.99
$1.79
Total:
Buy 10,000+ pieces and save 47%
$2.99
$1.59
Total:
x

6 People watching this product now!
Description

120ml 10 Panel Drug Test Cup with K2, MDMA and OPI2000

The Serenity 120ml 10 panel drug test cup with K2 brings together dedicated K2/Spice and MDMA assays with eight additional drug-screening panels.

Identified by SKU SM-CDOA-1104K-FUO, this configuration includes an OPI cutoff of 2,000 ng/mL and separate panels for THC, buprenorphine and oxycodone. Each labeled assay provides its own preliminary screening result.

Choose this model when your purchasing specification calls for the listed K2 and MDMA combination in a 120ml cup. It is the larger-capacity counterpart to the 90ml K2 and MDMA version, with the same listed drug panels and cutoff levels.

Cup capacity and drug coverage are separate purchasing considerations, so selecting the larger format does not add extra screening panels.

The combination is particularly important when comparing ten-panel products. Some alternatives include methadone, fentanyl or EtG in different panel arrangements. This SKU includes K2 and MDMA without dedicated fentanyl or methadone assays.

Matching the complete configuration helps you select the product that covers the substances specified in your testing procedure.

Before ordering, compare the panel list, cutoff values, capacity and labeled intended use. The table below identifies this product’s complete configuration, while our 10 panel drug test cup collection provides access to other combinations.

For repeat purchases, use the SKU to distinguish this 120ml cup from similarly named products.

10 Panel Drug Test Cup with K2 Cutoff Levels

The following table lists the ten drug panels and their screening cutoffs for SM-CDOA-1104K-FUO. These thresholds are product specifications; the cup does not provide a numerical measurement of the drug concentration in an individual sample.

Drug or Drug Class Abbreviation Cutoff Level
Amphetamines AMP 1,000 ng/mL
Buprenorphine BUP 10 ng/mL
Benzodiazepines BZO 300 ng/mL
Cocaine COC 300 ng/mL
Synthetic Cannabinoids (K2/Spice) K2 50 ng/mL
MDMA (Ecstasy) MDMA 500 ng/mL
Methamphetamine MET 1,000 ng/mL
Opiates OPI 2,000 ng/mL
Oxycodone OXY 100 ng/mL
Marijuana (THC) THC 50 ng/mL

Understanding the K2, MDMA and OPI2000 Panels

K2 and THC are separate assays in this configuration. Although each lists a 50 ng/mL cutoff, they target different substances and must be interpreted separately. The K2 panel should not be treated as coverage for every synthetic cannabinoid; consult the matching insert for the compounds evaluated, cross-reactivity and limitations.

MDMA also has its own panel, separate from the MET methamphetamine assay. Read the drug abbreviation beside each result area rather than combining the findings from similarly named substances.

For an OPI2000 drug test, the number identifies the listed opiate screening cutoff of 2,000 ng/mL. This differs from an OPI/300 configuration. Buprenorphine and oxycodone have separate assays, so the OPI result should not be used as a result for every opioid.

Compare the 120ml K2 Cup with Other Ten-Panel Options

Use the required cup capacity and drug combination to narrow your selection:

A larger capacity does not establish a different cutoff, additional drug coverage or a particular specimen fill requirement. Follow the specifications and instructions for the exact product you order.

How to Use a 10 Panel Drug Test Cup with K2

Follow the instructions supplied with SM-CDOA-1104K-FUO for specimen requirements, activation and the valid reading window.

  1. Check the product and package. Confirm the SKU and the K2, MDMA and OPI2000 configuration. Check the printed expiration date, package condition and storage instructions before opening the device.
  2. Collect the required specimen. Follow the collection procedure and specimen volume specified in the matching insert. The 120ml capacity is not a minimum fill requirement.
  3. Close the cup and start the test. Secure the lid and complete any activation steps described in the instructions. Keep the cup in the required position and use a timer to track the reading window.
  4. Read and record each drug panel. Check the control line before interpreting the test line. Read each labeled assay at the specified time and disregard changes appearing outside the permitted reading window.

For help matching the device to its instructions and understanding the assay lines, see our Serenity Cup drug test instructions.

How to use a Serenity Cup urine drug test and read the results

How to Read 10 Panel Drug Test Results

For the competitive drug-assay lines, use the control region marked C and the test region marked T. Interpret every labeled assay separately within the reading window specified in the supplied instructions.

Control Line C Test Line T Screening Result
Visible Visible, including a faint colored line Negative screen for that assay
Visible Absent Preliminary non-negative screen for that assay
Absent Visible or absent Invalid assay

A faint colored test line counts as a test line when the control line is present and the result is read within the specified window. Line darkness does not measure drug concentration.

If the control line is missing, the affected assay is invalid even when a test line appears. Review the procedure and repeat with a new device as directed by the insert. Do not report an invalid assay as negative or non-negative.

Screening results are preliminary. A non-negative result should be confirmed using an appropriate laboratory method, and a negative result does not establish that every drug is absent. For additional examples, read our guide to how to read a drug test cup.

Order the 120ml K2 and MDMA Cup by SKU

Use SM-CDOA-1104K-FUO when ordering this 120ml configuration. Including the SKU, cup capacity and K2/MDMA combination helps identify the correct product when comparing supplies or requesting a quote.

Review the quantity pricing displayed on this page for your order size. For larger purchases, request wholesale drug testing supply pricing with the product code, number of cups and delivery destination.

Frequently Asked Questions

What does OPI2000 mean on this drug test cup?

OPI2000 identifies the opiate panel and its listed screening cutoff of 2,000 ng/mL. It is a different cutoff from an OPI/300 configuration and does not provide a numerical measurement of the drug concentration in a sample.

Does this K2 and MDMA cup include fentanyl or methadone?

No dedicated fentanyl or methadone panel is listed for SM-CDOA-1104K-FUO. Its ten panels are AMP, BUP, BZO, COC, K2, MDMA, MET, OPI, OXY and THC.

Does the K2 panel detect every synthetic cannabinoid?

No universal coverage should be assumed. Check the matching product insert for the compounds evaluated by the K2 assay, cross-reactivity and limitations. The separate THC panel does not replace the K2 assay.

Does the 120ml cup test for more drugs than the 90ml version?

No. The 120ml and 90ml K2 and MDMA versions list the same ten drug panels and cutoff levels. They have different cup capacities, and each should be used according to its supplied instructions.

How much specimen does the 120ml cup require?

Use the specimen volume specified in the matching package insert. The 120ml specification describes cup capacity and should not be treated as the required collection volume.

What if a control line does not appear?

The affected assay is invalid, whether or not a test line appears. Review the testing procedure and repeat with a new device as directed by the insert. Do not report an invalid assay as negative or non-negative.

Forensic Use Only (FUO)

This product is intended for forensic drug screening according to its labeling and manufacturer’s instructions. It is not intended for clinical diagnosis or consumer at-home testing. Results are preliminary; non-negative results should receive laboratory confirmation where required. Before purchasing or using this product, please review our Forensic Use Only Policy & Customer Acknowledgement.

Additional information
Weight0.14 lbs
Dimensions5 × 3 × 3 in
Drug testedAMP, BUP, BZO, COC, K2/Spice, MDMA, MET, OPI/MOR, OXY, THC
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “120ml 10 Panel Drug Test Cup with K2, MDMA & OPI2000”
Shipping & Delivery

All orders will only be shipped same-day if they are placed before 3.00pm EST time. Also next day shipments will not be delivered on weekends and that the time taken on air shipments should be counted with business days.