6 Panel Drug Test Cup with Adulteration Testing – 90ml

Original price was: $4.19.Current price is: $1.69.

The Economy 6 Panel Drug Test Cup combines rapid urine screening for AMP, BZO, COC, MET, OPI and THC with specimen-validity checks for pH, specific gravity and creatinine. This compact 90ml CLIA-waived configuration provides preliminary results in approximately five minutes.

  • Six drug-screening panels
  • Three specimen-validity checks
  • AMP, BZO, COC, MET, OPI and THC
  • pH, specific gravity and creatinine
  • Integrated temperature strip
  • Compact 90ml collection cup
  • Bulk pricing and free shipping on 100 or more cups
Drugs Tested
AMP/1000, COC/300, BZO/300, MET/1000, OPI/2000, THC/50, PH/SG/CR
Buy 25 pieces and save 60%
$4.19
$1.69
Total:
$4.19
Buy 50 pieces and save 61%
$4.19
$1.65
Total:
Buy 100 pieces and save 62%
$4.19
$1.59
Total:
Buy 200 pieces and save 63%
$4.19
$1.55
Total:
Buy 400 pieces and save 64%
$4.19
$1.49
Total:
Buy 600 pieces and save 65%
$4.19
$1.45
Total:
Buy 800 pieces and save 67%
$4.19
$1.39
Total:
Buy 1,000 pieces and save 68%
$4.19
$1.35
Total:
Buy 2,000 pieces and save 69%
$4.19
$1.29
Total:
Buy 4,000 pieces and save 72%
$4.19
$1.19
Total:
Buy 6,000 pieces and save 74%
$4.19
$1.09
Total:
Buy 8,000 pieces and save 76%
$4.19
$0.99
Total:
Buy 10,000 pieces and save 79%
$4.19
$0.89
Total:
Buy 20,000+ pieces and save 81%
$4.19
$0.79
Total:
x

5 People watching this product now!
Description

6 Panel Drug Test with Adulteration and Specimen-Validity Checks

The 6 Panel Drug Test Cup with Adulteration Testing combines urine collection, six preliminary drug-screening panels and three specimen-validity indicators in one compact 90ml device.

This configuration screens for amphetamine, benzodiazepines, cocaine, methamphetamine, opiates and marijuana. It also evaluates pH, specific gravity and creatinine to help trained users identify urine characteristics that may indicate dilution or another specimen-integrity concern.

Results are generally available in approximately five minutes when the device is stored, collected, activated and interpreted according to its instructions. Any presumptive non-negative drug result or abnormal specimen-validity result should be handled according to the organization’s written testing procedures.

6 panel drug test list

This 6 panel urine screen detects the following substances and includes built-in specimen validity testing to help verify sample integrity:

Drug / Test Abbreviation Cutoff Level Typical Detection Time
Amphetamines AMP 1000 2–4 days
Cocaine COC 300 2–4 days
Benzodiazepines BZO 300 3–7 days (long-acting up to 30 days)
Methamphetamine MET 1000 2–4 days
Opiates OPI 2000 2–4 days
Marijuana (THC) THC 50 3–30 days
Specimen Validity pH / SG / CR Indicates sample integrity

Cutoff concentration and detection window have different meanings. The cutoff is the concentration used by the device to produce a preliminary screening result. Detection windows vary according to the substance, pattern of use, metabolism, hydration, specimen concentration and other factors.

Review our educational guides to drug test cutoff levels and urine drug detection times for additional information.

What Does Adulteration Testing Measure?

The cup includes three specimen-validity indicators:

Creatinine

Creatinine is naturally present in urine. An unusually low creatinine result may be associated with a dilute specimen, although proper interpretation depends on the product instructions and the organization’s testing protocol.

Specific gravity

Specific gravity evaluates urine concentration relative to water. An abnormal result may indicate excessive dilution or another specimen-integrity concern.

pH

The pH indicator evaluates how acidic or alkaline the specimen is. An unusual pH result may result from chemical interference, storage conditions, specimen deterioration or physiological factors.

These indicators provide preliminary information. They do not identify which substance was added, prove intentional tampering or replace laboratory specimen-validity testing.

Laboratory specimen-validity procedures also use creatinine, specific gravity and pH, but laboratory testing follows different analytical and regulatory requirements. The Department of Transportation describes these laboratory measurements in its official urine specimen-validity requirements.

Adultarents chart

How to Use the Test Cup

  1. Verify that the device has not expired and that the sealed package is undamaged.
  2. Allow the test to reach the temperature required by the instructions.
  3. Collect urine directly in the 90ml cup.
  4. Secure the screw-on lid completely.
  5. Check the temperature indicator within the specified collection period.
  6. Activate or uncover the drug and specimen-validity panels as directed.
  7. Read the drug results at the exact time stated in the product insert.
  8. Compare pH, specific gravity and creatinine colors with the supplied chart at the required time.

For the drug panels:

  • Control line and test line: Negative screening result.
  • Control line without a test line: Presumptive non-negative result.
  • No control line: Invalid panel; repeat the test with a new device.

A faint test line generally indicates a negative result when it appears within the correct reading period. Follow the supplied instructions because activation and interpretation requirements can vary.

See our complete guide explaining how to read a drug test cup.

How to read Cup

Why Choose This Six-Panel Configuration?

This product may be appropriate when an organization needs common-drug screening plus additional information about specimen integrity.

Potential benefits include:

  • Collection and testing in one device
  • Six commonly requested drug panels
  • Dedicated benzodiazepine screening
  • Integrated pH, specific-gravity and creatinine indicators
  • Temperature verification
  • Compact 90ml design
  • Approximately five-minute preliminary results
  • Quantity-based pricing

Because six-panel products contain different drug combinations, buyers should compare all 6 panel drug test cups before ordering.

Who May Use This 6 Panel Urine Drug Test?

Subject to the product documentation and applicable testing policies, this configuration may be considered by:

  • Employers and human-resources departments
  • Staffing and employment agencies
  • Treatment and rehabilitation programs
  • Sober living and recovery organizations
  • Occupational-health providers
  • Clinics and physician offices
  • Mobile drug-testing services
  • Correctional and probation programs
  • Schools and community organizations

Testing organizations should maintain written procedures addressing collection, donor identification, result interpretation, confirmation, confidentiality and abnormal specimen-validity results.

How to Handle Abnormal Validity Results

An abnormal pH, specific-gravity or creatinine result should not automatically be described as intentional tampering.

Possible next steps may include:

  1. Documenting the observed result
  2. Reviewing the product instructions
  3. Checking whether the result was read at the correct time
  4. Following the organization’s written recollection policy
  5. Sending the specimen to an appropriate laboratory when required
  6. Consulting the organization’s medical review or compliance personnel

Do not make a final employment, clinical or legal determination based only on the cup’s specimen-validity color pad.

CLIA-Waived Status

The current product listing identifies this configuration as CLIA waived. Before publishing or relying on that designation, verify the manufacturer, product name, catalog number, panel configuration and current regulatory documentation.

CLIA-waived status does not mean the product is suitable for every testing program, exempt from applicable state laws or approved as a substitute for federally regulated laboratory testing.

Clinical purchasers can review our CLIA-waived drug test cups guide for additional selection information.

Is This Cup Suitable for DOT Testing?

This instant six-panel cup should not be marketed as a replacement for DOT-regulated drug testing. DOT testing follows a defined laboratory-based five-panel program and the procedures established under 49 CFR Part 40.

Organizations conducting both DOT and non-DOT testing should keep their policies, collection procedures and documentation separate.

Compare Related 6 Panel Options

Choose this product when you need:

  • AMP, BZO, COC, MET, OPI and THC
  • pH, specific gravity and creatinine
  • A compact 90ml economy cup

Buyers who need the same compact format without specimen-validity checks can compare the economy 6 panel urine drug test cup.

Programs needing fentanyl, EtG, kratom, K2 and xylazine should instead consider the 6 panel specialty drug test cup.

Bulk 6 Panel Drug Test Cups with Adulteration Testing

DrugTestingCup.com offers quantity-based pricing for organizations requiring recurring or high-volume testing inventory.

Purchasing benefits include:

  • Volume discounts
  • Free shipping on orders of 100 or more cups
  • Same-day shipping on qualifying orders placed before 3:00 p.m. Eastern Time
  • Recurring-order savings
  • Distributor and multi-location pricing
  • Support with configuration selection and documentation

High-volume organizations can also review our wholesale drug testing supplies or contact us for current inventory and large-order pricing.

Frequently Asked Questions

What drugs are included in this six-panel test?

This configuration screens for amphetamine, benzodiazepines, cocaine metabolite, methamphetamine, opiates and marijuana metabolite.

What adulteration indicators are included?

The cup includes specimen-validity checks for pH, specific gravity and creatinine. These indicators help identify abnormal urine characteristics but do not prove intentional tampering.

Are the specimen-validity checks counted as drug panels?

No. The product has six drug panels plus three separate specimen-validity indicators. pH, specific gravity and creatinine do not detect drugs.

What is the difference between the temperature strip and the validity checks?

The temperature strip evaluates specimen temperature shortly after collection. The validity indicators evaluate selected urine characteristics involving acidity, concentration and creatinine.

Does an abnormal validity result mean the donor cheated?

Not necessarily. An abnormal result may have several causes and should be evaluated under the organization’s written procedures. Laboratory testing may be appropriate.

Is this 6 panel drug test CLIA waived?

The current product listing identifies this configuration as CLIA waived. Verify the exact manufacturer, catalog number, configuration and current documentation before relying on that designation.

How quickly are results available?

Drug-screening results are generally available in approximately five minutes. Specimen-validity pads must be compared with the supplied chart at the times stated in the instructions.

Are presumptive non-negative results final?

No. A presumptive non-negative drug result should be confirmed using an appropriate laboratory method before a final determination is made.

Product Specifications

Specification Details
Product Economy 6 Panel Drug Test Cup with Adulteration Testing
Specimen Human urine
Capacity 90ml
Drug panels AMP, BZO, COC, MET, OPI and THC
Validity checks pH, specific gravity and creatinine
Result time Approximately five minutes
Temperature strip Included
Format Integrated collection and screening cup
Use Single-use preliminary screening
Regulatory status CLIA waived—verify current documentation
Additional information
Weight0.1 lbs
Cupsingle cup
Drug testedADLTX, AMP, BZO, COC, MET, OPI/MOR, THC
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “6 Panel Drug Test Cup with Adulteration Testing – 90ml”
Shipping & Delivery

All orders will only be shipped same-day if they are placed before 3.00pm EST time. Also next day shipments will not be delivered on weekends and that the time taken on air shipments should be counted with business days.